KEYPAD OPTIONS *190-*196 (NOTE: Options for keypad address 16 are set by the factory and cannot be changed.)
NOTE: Each keypad must be assigned a unique address. Keypads programmed with the same address will give unpredictable results.
190 KEYPAD 2 DEVICE ADDRESS 17
[0] [0]
Partition/ Sound
Enable
†FA168CPS: enter partition
FA148CP: 1 = enable
0 = disable
Partition: 0 = keypad disabled; 1-3 = part. no. (3 = com)
Sound: 0 = no suppression
1 = suppress arm/disarm and E/E beeps
2 = Suppress chime beeps only
3 = suppress arm/disarm, E/E, and chime
beeps
Part./Enable
Sound
191 KEYPAD 3 DEVICE ADDRESS 18
[0] [0]
See field 190 for entries.
192 KEYPAD 4 DEVICE ADDRESS 19
[0] [0]
See field 190 for entries.
193 KEYPAD 5 DEVICE ADDRESS 20
[0] [0]
See field 190 for entries.
194 KEYPAD 6 DEVICE ADDRESS 21
[0] [0]
See field 190 for entries.
195 KEYPAD 7 DEVICE ADDRESS 22
[0] [0]
See field 190 for entries.
196 KEYPAD 8 DEVICE ADDRESS 23
[0] [0]
See field 190 for entries.
197 EXIT TIME DISPLAY INTERVAL
[0]
0 = no display; 1-5 = seconds between display refresh
NOTE: If enabled and using only 2-digit fixed-word
keypads (e.g., FA245RF), do not set exit delay time
greater than 96 seconds. See Inst. Instr. for explanation.
198 DISPLAY PARTITION NUMBER
(FA168CPS; for Alpha Display Keypads)
[0]
0 = no; 1 = yes (partition no. appears on Alpha Display)
199 ECP FAIL DISPLAY
[0]
0 = 3-digit display (“1” + device address)
1 = 2-digit fixed-display as “91”
Zone Type Definitions
(see Installation and Setup Guide for detailed explanations and applications)
Type Title Definition
00 Zone Not Used Assign this zone type if the zone is not used.
01 Entry/Exit Burglary no. 1
Provides entry delay if the control is armed in the Away or Stay modes.
Exit delay begins whenever the control is armed, regardless of the arming mode selected.
02 Entry/Exit Burglary no. 2
Provides a secondary entry delay, in same manner as entry delay #1.
03 Perimeter Burglary
Provides an instant alarm if the zone is faulted when the panel is armed in any mode.
04 Interior Follower
When armed in Away mode, provides a delayed alarm (using the programmed entry delay time) if the entry/exit zone
is faulted first. Otherwise this zone type gives an instant alarm.
Bypassed automatically when the panel is armed in the Stay or Instant modes.
05 Trouble by Day/Alarm by Night
Provides an instant alarm if faulted when armed in the Away, Stay, Instant or Maximum.
During the disarmed state (day), the system will provide a latched trouble sounding from the keypad (and a central
station report, if desired).
06 24-hour Silent Alarm
Emergency button zone. Sends a report but provides no keypad display or sounding.
07 24-hour Audible Alarm
Emergency button zone. Sends a report and sounds alarm at the keypad and ext. sounder.
08 24-hour Auxiliary Alarm
Emergency button zone, or for a zone containing monitoring devices such as water or temperature sensors. Sends a
report and sounds alarm at the keypad (not ext. sounder).
09 Fire
Provides a fire alarm on short circuit and a trouble condition on open circuit. A fire alarm produces a pulsing bell
output. This zone type is always active and cannot be bypassed.
Hardwired zone 1 should be used with 2-wire smoke detectors; zones 2-8 can be used with 4-wire smoke detectors;
any wireless zone can be used as a fire zone.
10 Interior w/Delay
Provides entry delay if tripped when the panel is armed Away. Delay begins whenever zone is violated, regardless of
whether or not an entry/exit delay zone was tripped first.
12 Monitor Zone
Works as a dynamic monitor of a zone fault/trouble. In the case of a short/open, the message, "ALARM-24 Hr. Non-
Burg. -#XXX " (where XXX is the zone number) will be sent to the Central Station. The system keypad will display a
“check” message indicating the appropriate zone (but keypad beeping does not occur). Upon restoral of the zone, the
message, "RESTORE-24 Hr. Non-Burg. -#XXX " will be sent to the Central Station.
The “check” message will automatically disappear from the keypad dynamically when the zone restores; a user code
+ off sequence is not needed to reset the zone.
Faults of this zone type are independent of the system, and can exist at the time of arming without interference.
Since this is a “trouble” zone type, do not use this zone type with relays set to activate upon “alarm.”
14 Carbon Monoxide
The bell output pulses when this zone type is faulted. Always active, cannot be bypassed.
16 Fire w/Verification
Provides a fire alarm when zone is shorted, but only after alarm verified.
Provides a trouble response when zone is open.
20 Arm-Stay
Button zone. Arms the system in Stay mode when the zone is activated.
User code for button must be assigned.
21 Arm-Away
Button zone. Arms the system in Away mode when the zone is activated.
User code for button must be assigned.
22 Disarm
Button zone. Disarms the system when the zone is activated.
User code for button must be assigned.
23 No Alarm Response
Can be used on a zone when an output relay action is desired, but with no accompanying alarm (e.g., lobby door
access).
24 Silent Burglary
Provides an instant alarm, with NO audible indication at any keypad or external sounder, if the zone is faulted when
the system is armed in any mode. A report is sent.
77 Keyswitch
Assign to zone wired to a keyswitch.
81 AAV Monitor Zone
Assign to zone connected to AAV module.
90-93 Installer Defined
These zone types can be programmed for custom responses. See data fields *182-*185.
UL: Zone types 90-93 may not be used as fire or burglar zones in fire or UL burglar alarm installations.